Pro-face GP-2500 Especificações Página 1

Consulte online ou descarregue Especificações para não Pro-face GP-2500. Pro-face GP-2500 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 51
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1/51
Easy! Smooth!
GP-2500 Series->GP4000 Series
Replacement Guidebook
5
th
Edition 2014.11
Copyright © 2014.11 Digital Electronics Corporation. All Rights Reserved.
Vista de página 0
1 2 3 4 5 6 ... 50 51

Resumo do Conteúdo

Página 1 - Replacement Guidebook

1/51 Easy! Smooth! GP-2500 Series->GP4000 Series Replacement Guidebook 5th Edition 2014.11 Copyright © 2014.11 Digital Electronics Corporati

Página 2 - Safety Information

10/51 Chapter 2 Compatibility of Hardware 2.1 Locations of connector Connector locations on GP-2500 series and GP-4501TW are as follows: GP-2500T

Página 3

11/51 GP-4501TW Interface names GP-2500T/S/L GP-2501T/S/L GP-4501TW 1 Power Input Terminal Block (AC/DC type) Power Connector (DC type) 2 Seri

Página 4

12/51 2.2 Touch Panel specifications GP-4501TW adopts the Analog type. For the Analog type, even if you touch two points at the same time, it’s re

Página 5 - CHAPTER 5 APPENDIX 49

13/51 2.3 Display Colors (for GP-2500L/2501L only) The display color of GP-2500L/2501L is monochrome, but GP-4501TW has a TFT color LCD. After rep

Página 6

14/51 2.4 Transfer cable To transfer screen data to GP-4501TW, use a USB transfer cable or Ethernet. The USB cables that can be used for GP-4501TW

Página 7

15/51 and the functions using the CF card, use a SD card or a USB flash drive instead. * When using a SD card with GP-4501TW, please verify it su

Página 8

16/51 2.6.5 Isolation Unit The isolation unit for GP-2500 series (CA2-ISOALL232-01, CA2-ISOALL422-01) cannot be used for GP-4501TW. You can use RS

Página 9

17/51 2.9 Power Consumption The power consumption of GP-2500 series is different from that of GP-4501TW. AC Type DC Type GP-2500T 50VA or le

Página 10

18/51 (4) Click [SRAM Information] to see SRAM size. 2.12 Other Notes  Do not expose GP4000 series to direct sunlight.  Do not use GP4000 se

Página 11

19/51 Chapter 3 Replacement Procedure 3.1 Work Flow Receive screen data from GP-2500 series. *1 Convert GP-2500 s

Página 12

2/51 Preface This guidebook introduces the procedures to replace a unit in GP-2500 series with a GP-4501TW unit. Model in use Recommended Subst

Página 13

20/51 3.2 Preparation Requirements for receiving screen data from GP-2500 series. *1 GP-2500T: PC in which GP-PRO/PBIII for Windows V5.0 or later

Página 14

21/51 (1) Connect a transfer cable to the GP-2500 series. (2) Start up GP-PRO/PBIII for Windows and click the [Transfer] icon on the Project Ma

Página 15

22/51 (4) In the Communication Port field, select [COM], specify the COM port to which the cable is connected, and click [OK]. If you use a USB

Página 16

23/51 (5) Select the [Transfer] menu and click [Receive...]. (6) Specify the location to save the received screen data at and the project file n

Página 17

24/51 3.4 Convert screen data with the Project Converter Convert a project file (*.prw) for GP-2500 series with the GP-Pro EX’s Project Convert

Página 18

25/51 (4) In [Convert-To], designate a GP-Pro EX’s project file (*.prx). Click the [Browse…] button and enter a new [File Name] (e.g.: “Produc

Página 19

26/51 NOTE When a convert-to file exists, the window that confirms whether or not to overwrite the file is displayed.

Página 20

27/51 (5) Click [Convert] and start the conversion. (6) If you are asked about the [Convert-To] type as shown below, select a replacement model’

Página 21

28/51 If an error message is displayed during conversion If an error message is displayed during conversion, refer to [Project Converter Error M

Página 22

29/51 (7) After conversion, the [Save convert information] dialog box appears. If you click [Save], you can save the conversion information in a

Página 23

3/51 GP4000 Series Model Number GP4000 series model number partly differs depending on a specification. Before placing an order, please make sur

Página 24

30/51 Select a folder (e.g.: “Database”) and click [OK]. If you click the [Make New Folder] button, you can create a new folder at any location.

Página 25

31/51 (1) Open the converted project file (*.prx) on GP-Pro EX. (2) Click GP-Pro EX’s [System Settings]->[Display] and there change the Displ

Página 26

32/51 ・ If the following symptoms appear on Microsoft Windows® 7, go to updating “USB Data Transfer Driver” on [OtasukePro!] for

Página 27

33/51 (3) On the GP-Pro EX’s State Toolbar, click the [Transfer Project] icon to open the Transfer Tool. To transfer a different project file, cl

Página 28

34/51 (6) The following dialog box appears during transfer and you can check the communication status. (The display unit enters the Transferring m

Página 29

35/51 3.7 Differences of software 3.7.1 Differences after conversion Check the differences of screen data after conversion from GP-PRO/PBIII to

Página 30

36/51 29 D Script starts right after screen change or power on. (Compatibility of D Script Trigger Condition) 30 The position shifts when loading

Página 31

37/51 Chapter 4 Communication with Device/PLC 4.1 Drivers More connectable drivers will be added. For the devices/PLC each driver supports, see [C

Página 32

38/51 4.3 Signals of COM ports 4.3.1 Signals of COM1 For GP-2500 series RS-232C or RS-422 (socket)

Página 33

39/51 For GP-4501TW RS-232C (plug) *1: RI and VICC of Pin 9 are switched on the software. VCC Output is not protected from overcurrent. Ple

Página 34

4/51 Contents PREFACE 2 SAFETY INFORMATION 2 HAZARD OF OPERATOR INJURY, OR UNINTENDED EQUIPMENT DAMAGE2 GP4000 SERIES MODEL NUMBER 3 CONTENTS

Página 35

40/51 4.3.2 Signals of COM2 For GP-2500T/S/L RS-232C (plug) For GP-2501T/S/L N/A For GP-4501TW RS-422/485 (plug)

Página 36

41/51 4.4 Multilink Connection For GP-4501TW, some communication drivers do not support multi-link connection (n:1) via RS-422. When converting th

Página 37

42/51 4.6 Cable Diagram at the time of replacement The connection cable for GP-2500 series can be used for GP-4501TW. But please note that there a

Página 38

43/51 4.6.1 When using a RS-232C connection cable GP-2500 series System Configuration (connecting to COM1) GP-4501TW System Configuration (conne

Página 39

44/51 * For GP-2500T/S/L only: GP-2500T/S/L System Configuration (connecting to COM2) GP-4501TW System Configur

Página 40

45/51 4.6.2 When using a RS-422 connection cable GP-2500 series System Configuration (connecting to COM1) GP-4501TW System Configuration (conne

Página 41

46/51 NOTE When using a terminal block adapter (GP070-CN10-O), we recommend you to replace it with a terminal block conversion adapter (PFXZCBADT

Página 42

47/51 When using Mitsubishi A/QnA series(CPU Direct) connection cable(GP2000-CBLA/5M-01) * Including User-created cable 9/25-pin Conversion Cabl

Página 43

48/51 When using Mitsubishi A/QnA series(CPU Direct) connection cable(GP2000-CBLFX/5M-01, GP2000-CBLFX/1M-01)

Página 44

49/51 Chapter 5 Appendix 5.1 Changing the setting of the external media to use If a CF card has been used for GP-PRO/PBIII, after GP-2500 series i

Página 45

5/51 2.11 BACKUP MEMORY (SRAM) 17 2.12 OTHER NOTES 18 CHAPTER 3 REPLACEMENT PROCEDURE 18 3.1 WORK FLOW 19 3.2 PREPARATION 20 3.3 RECEIVE SCRE

Página 46

50/51 iii. Click the [Browse] button and specify a destination folder. iv. Click [OK] to confirm the setting. v. Click [Project]->[

Página 47 - GP4000 series

51/51 ii. The current setting is displayed. iii. After changing it, click [OK] to confirm the setting. iv. Click [Project]->[Save] to sav

Página 48

6/51 Chapter 1 Specification Comparison 1.1 Specifications of GP-2500T/S/L and GP-4501TW GP-2500T/S/L GP-4501TW Display Type GP-2500T TFT co

Página 49 - Chapter 5 Appendix

7/51 CF Card I/F ✔ - ->See 2.5.4 SD Card I/F - NEW! ✔ USB I/F Type A - NEW! ✔ ->See 2.4 Type mini B Tool Connector I/F ✔ - Printer I/F Centr

Página 50

8/51 1.2 Specifications of GP-2501T/S/L and GP-4501TW GP-2501T/S/L GP-4501TW Display Type GP-2501T TFT color LCD TFT color LCD GP-2501S STN

Página 51

9/51 Ethernet I/F - NEW! 10BASE-T/100BASE-TX CF Card I/F ✔ - ->See 2.5.4 SD Card I/F - NEW! ✔ USB I/F Type A - NEW! ✔ ->See 2.4 Type mini B